QoS Commands
OmniSwitch CLI Reference Guide November 2009 page 38-17
qos stats interval
Configures how often the switch polls network interfaces for statistics about QoS events.
qos stats interval seconds
Syntax Definitions
seconds The number of seconds before the switch polls network interfaces for
statistics. The range is 10–3600.
Defaults
Platforms Supported
OmniSwitch 6250
Usage Guidelines
Change the statistics interval to a smaller interval if you want to monitor QoS events.
Change the statistics interval to a larger interval if you want to free some switch memory.
Examples
-> qos stats interval 30
Release History
Release 6.6.1; command was introduced.
Related Commands
MIB Objects
alaQoSConfigTable
alaQoSConfigStatsInterval
parameter default
seconds 60
show qos statistics Displays statistics about the QoS configuration.