AAA Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 43-75
show user lockout-setting
Displays the global user lockout settings for the switch.
show user lockout-setting
Syntax Definitions
N/A
Defaults
N/A
Platforms Supported
OmniSwitch 6250
Usage Guidelines
The global lockout settings include parameter values that determine the length of a user observation
window, the amount of time a locked user remains locked, and the number of failed password login
attempts allowed.
Examples
-> show user lockout-setting
Lockout Setting:
Observation window: 30 (minutes)
Duration: 200 (minutes)
Threshold: 20
Release History
Release 6.6.1; command was introduced.
output definitions
Observation window The amount of time, in minutes, during which the number of failed
password login attempts are counted. Configured through the user
lockout-window command.
Duration The amount of time, in minutes, that a locked user account remains
locked out of the switch. Configured through the user lockout-dura-
tion command.
Threshold The maximum number of failed password login attempts allowed
before the user is locked out of the switch. Configured through the user
lockout-threshold command.