CMM Commands
page 1-2 OmniSwitch 6250 CLI Reference Guide November 2009
reload
Reboots the CMM to its startup software configuration.
reload [primary | secondary] [with-fabric] [in [hours:] minutes | at hour:minute [month day | day
month]]
reload [primary | secondary] [with-fabric] cancel
Syntax Definitions
primary | secondary Reboot the primary or secondary CMM to its startup software configu-
ration. If the primary CMM is already running the startup version, a
primary reboot will result in a secondary takover.
in [hours:] minutes Optional syntax. Schedules a reload of the software to take effect in the
specified minutes or hours and minutes within the next 24 hours.
at hour:minute Optional syntax. Schedules a reload of the software to take place at the
specified time using a 24-hour clock. If you do not specify the month
and day, the reload takes place at the specified time on the current day
provided the specified time is later than the time when the CLI
command is issued. If the specified time is earlier than the current time,
the reload will take place on the following day.
month day | day month The name of the month and the number of the day for the scheduled
reload. Specify a month name and the day number. It is unimportant if
the month or day is first. See examples below for further explanation.
cancel Cancels a pending time delayed reboot.
Defaults
N/A
Platforms Supported
OmniSwitch 6250
Usage Guidelines
This command causes the specified CMM to reboot. If no CMM is specified, the primary CMM
reboots.
If a reload command is issued, and another reload is currently scheduled, a message appears informing
the user of the next reload time and asks for confirmation to change to the new reload time.
If the switch has a redundant CMM and the primary CMM is rebooted, the switch will fail over to the
secondary CMM. For more information on CMM failover, see “Managing CMM Directories” in the
OmniSwitch 6250 Switch Management Guide.
If the switch is part of a stacked configuration consisting of three or more switches, the next switch in
“idle” mode becomes the secondary CMM, and the original primary CMM becomes “idle.” For more
information on stacks, see “Managing Stacks” in the appropriate Hardware Users Guide.The cancel
keyword stops a pending reboot.