Ethernet Port Commands
page 20-32 OmniSwitch 6250 CLI Reference Guide November 2009
interfaces hybrid speed
Configures interface line speed on combo ports.
interfaces slot[/port[-port2]] speed hybrid {fiber | copper} {auto | 10 | 100 | 1000 | 10000 | max {100 |
1000}}
Syntax Definitions
slot Slot number you want to configure.
port Port number of the interface you want to configure.
port2 Last port number in a range of ports you want to configure.
fiber Specifies that configuration changes will be made to the SFP port(s).
copper Specifies that changes will be made to the copper RJ-45 port(s).
auto The switch will automatically set the line speed to match the attached
device (auto-sensing).
10 Sets the interface to 10 Mbps.
100 Sets the interface to 100 Mbps.
1000 Sets the interface to 1 Gigabit.
10000 Sets the interface to 10 Gigabit. This option is currently not supported.
max 100 Sets the maximum speed to 100 megabits.
max 1000 Sets the maximum speed to 1000 megabits (1 Gigabit)
Defaults
Platforms Supported
OmniSwitch 6250
Usage Guidelines
The MIB table and MIB object listed in the “MIB Objects” section below apply to the inactive configured
media only. See the “MIB Objects” section in the interfaces speed section for the MIB table and MIB
object for the active configured media.
parameter default
auto | 10 | 100 | 1000 |
10000 | max 100 | max
1000
auto