Ethernet OAM Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 25-31
ethoam fault-alarm-time
Configures the timeout value for the Fault Notification Generation Alarm time that specifies the time
interval during which one or more defects should be detected before the fault alarm is issued.
ethoam fault-alarm-time centiseconds endpoint endpoint_id domain {domain_name | mac_address}
association association_name
no ethoam fault-alarm-time endpoint endpoint_id domain {domain_name | mac_address}
association association_name
Syntax Definitions
centiseconds The Fault Notification Generation Alarm timeout value, in centi
seconds. The valid range is 250–1000.
endpoint_id Specifies the MEP of a specific MA. The valid range is 1–8191.
mac_address Specifies the CFM system MAC address.
domain_name Specifies the domain name. For more information on the different
formats of the domain name, refer to ethoam domain command on
page 25-3.
association_name Name of the Ethernet OAM Association. Up to 48 (minus the domain
name length) characters may be used.
Defaults
Platforms Supported
OmniSwitch 6250-Metro Models
Usage Guidelines
Use the no form of this command to restore the Fault Notification Generation Alarm timeout value to
its default value.
The Fault Notification Generation Alarm timeout value is configurable per MEP.
Examples
-> ethoam fault-alarm-time 10 endpoint 100 domain esd.alcatel-lucent.com associa-
tion alcatel_sales
-> no ethoam fault-alarm-time endpoint 100 domain esd.alcatel-lucent.com associa-
tion alcatel_sales
Release History
Release 6.6.1; command was introduced.
parameter default
centiseconds 250