EasyManua.ls Logo

Alcatel-Lucent OmniSwitch 6250 - Efm-Oam Port Propagate-Events

Alcatel-Lucent OmniSwitch 6250
2018 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LINK OAM Commands
OmniSwitch 6250 CLI Reference Guide November 2009 page 26-15
efm-oam port propagate-events
Configures whether or not the specified port or range of ports will propagate local event notifications to
the remote peer.
efm-oam port slot/port[-port2] propagate-events {critical-event | dying-gasp} {enable | disable}
Syntax Definitions
slot/port The slot number for the module and the physical port number on that
module (e.g. 3/1 specifies port 1 on slot 3).
-port2 Specifies the last port in the range of ports.
critical-event Configures the notification status for critical events.
dying-gasp Configures the notification status for dying gasp events.
enable Enables the notification of critical-event or dying-gasp events to the
peer.
disable Disables the notification of critical-event or dying-gasp events to the
peer.
Defaults
By default, the notification status for both critical-event and dying-gasp events is set to enabled.
Platforms Supported
OmniSwitch 6250.
Usage Guidelines
When the system is set for critical event or a dying-gasp event, the local OAM entity indicates the
event through the OAMPDU flags to its peer OAM entity.
In case of port admin down, the OAM IFU-PDU with dying-gasp bit set will be sent to peer as soon as
a failure is detected and transmission will continue till the specific port actually goes down.
In case of takeover or reload of the switch, the OAM IFU-PDU with dying-gasp bit set will be sent to
peer as soon as a failure is detected and transmission will continue till the specific device actually goes
down.
The information PDUs with dying gasp bit set is transmitted towards peer as soon as link-down is
detected at NI. However, if there is a link flap (i.e link comes again) before the expiry of link-flap
timer, then normal information PDU transmission with dying-gasp bit reset shall resume. This will
cause clearing of alarms or trap on the peer port.
Examples
-> efm-oam port 1/1 propagate-events critical-event enable
-> efm-oam port 1/1 propagate-events critical-event disable
-> efm-oam port 2/1-10 propagate-events dying-gasp enable
-> efm-oam port 2/1-4 propagate-events dying-gasp disable

Table of Contents

Other manuals for Alcatel-Lucent OmniSwitch 6250

Related product manuals