Slot Numbering Managing OmniSwitch 6400 Series Stacks
page 6-22 OmniSwitch 6400 Series Hardware Users Guide August 2008
When the stack comes up following the reboot, the manually-configured slot numbers display as follows:
The stack set slot command can also be used to manually correct duplicate saved slot assignments within
the stack topology. Refer to pages 6-12 through 6-14 for detailed information.
Reverting to the Dynamic Slot Numbering Model
To clear the boot.slot.cfg files from the stack’s /flash directories, use the stack clear slot command on all
modules and then reboot the stack. For example:
-> stack clear slot 1
-> stack clear slot 2
-> stack clear slot 3
-> stack clear slot 4
-> stack clear slot 5
-> stack clear slot 6
-> stack clear slot 7
-> stack clear slot 8
-> reload all
The commands shown above clear the saved slot information from all modules in an eight-module stacked
configuration and then reboot the stack. Because the system software no longer has preassigned slot infor-
mation to read during the boot process, the stack uses the dynamic slot number assignment method
described on page 6-19.
Slot 4 - Idle
Slot 5 - Idle
Slot 6 - Idle
Slot 7 - Idle
Slot 8 - Idle
Slot 1 - Primary
Slot 2 - Secondary
Slot 3 - Idle