Configuring 802.1AB Configuring 802.1AB
page 13-10 OmniSwitch 6800/6850/9000 Network Configuration Guide March 2008
Setting the Transmit Hold Multiplier Value
To set the transmit hold multiplier value, enter the lldp transmit hold-multiplier command. For exam-
ple, to set the transmit hold multiplier value to 2, enter:
-> lldp transmit hold-multiplier 2
Note: The Time To Live is a multiple of the transmit interval and transmit hold-multiplier.
Setting the Transmit Delay
To set the minimum time interval between successive LLDPDUs transmitted, enter the lldp transmit
delay command. For example, to set the transmit delay value to 20 seconds, enter:
-> lldp transmit delay 20
By default, the transmit delay is less than or equal to the multiplication of the transmit interval and 0.25.
Setting the Reinit Delay
To set the time interval that must elapse before the current status of a port is reinitialized after a status
change, enter the lldp reinit delay command. For example, to set the reinit delay to 7 seconds, enter:
-> lldp reinit delay 7
Setting the Notification Interval
To set the time interval that must elapse before a notification about the local system Management Informa-
tion Base (MIB) change is generated, enter the lldp notification interval command. For example, to set
the notification value to 130 seconds, enter:
-> lldp notification interval 130
Note: In a specified interval, generating more than one notification-event is not possible.