EasyManua.ls Logo

Alcatel-Lucent OmniSwitch 6800 Series - Page 883

Alcatel-Lucent OmniSwitch 6800 Series
926 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring Ethernet Ports Combo Port Application Example
OmniSwitch 6800/6850/9000 Network Configuration Guide March 2008 page 37-25
3 Verify that combo ports 1/47 and 1/48 are set to the default setting of preferred fiber (which will make
the SFP connectors 1/47 and 1/48 the primary connections while copper combo ports 1/47 and 1/48 will
only become active if the equivalent SFP connectors go down) with the show interfaces status command
as shown below:
-> show interfaces 1/45-48 status
DETECTED CONFIGURED
Slot/ AutoNego Speed Duplex Hybrid Speed Duplex Hybrid Trap
Port (Mbps) Type (Mbps) Mode LinkUpDown
-----+--------+------+------+------+--------+------+------+------
1/45 Enable - - - 100 Auto FC -
1/45 Enable - - - 1000 Full FC -
1/46 Enable - - - 100 Auto FC -
1/46 Enable - - - 1000 Full FC -
1/47 Enable - - - 1000 Full PF -
1/47 Enable - - - 100 Auto PF -
1/48 Enable - - - 1000 Full PF -
1/48 Enable - - - 100 Auto PF -
FF - ForcedFiber PF - PreferredFiber F - Fiber
FC - ForcedCopper PC - PreferredCopper C - Copper
In the output above combo ports 1/47 and 1/48 are set to preferred fiber. (To configure combo ports as
preferred fiber use the interfaces hybrid preferred-fiber command.)