Quick Steps for Configuring ERP with VLAN Stacking Configuring ERP
page 14-10 OmniSwitch AOS Release 6 Network Configuration Guide September 2009
Quick Steps for Configuring ERP with VLAN
Stacking
The following steps provide a quick tutorial for configuring ERP with VLAN Stacking:
1 Create a VLAN Stacking SVLAN 1001 using the ethernet-service command.
-> ethernet-service svlan 1001
2 Create a VLAN Stacking service and associate the service with SVLAN 1001 using the ethernet-
service service-name command.
-> ethernet-service service-name CustomerA svlan 1001
3 Configure ports 1/1 and 1/2 as VLAN Stacking Network Network Interface (NNI) ports, associate the
ports with SVLAN 1001, and configure them for use with ERP using the ethernet-service svlan nni
command.
-> ethernet-service svlan 1001 nni 1/1 erp
-> ethernet-service svlan 1001 nni 1/2 erp
4 Create ERP ring ID 1 and associate the two NNI ports to the ring using the erp-ring command.
-> erp-ring 1 port 1/1 port2 1/2 service-vlan 1001 level 5
5 Configure the RPL on one node using the erp-ring rpl-node command.
-> erp-ring 1 rpl-node port 1/1
6 Create additional SVLANs to add to the ring using the ethernet-service command.
-> ethernet-service svlan 1002
-> ethernet-service svlan 1003
-> ethernet-service svlan 1004
-> ethernet-service svlan 1005
7 Configure the SVLANs created in Step 6 as ERP protected VLANs using the erp-ring protected-vlan
command.
-> erp-ring 1 protected-vlan 1002-1005
Note that when two VLAN Stacking NNI ports are associated with the same SVLAN and both those ports
will serve as the ring ports for the node, the SVLAN is automatically added to the list of protected
SVLANs for the ERP ring. For example, the following commands designate SVLAN 1002 as a protected
VLAN:
-> ethernet-service svlan 1002 nni 1/1 erp
-> ethernet-service svlan 1002 nni 1/2 erp
8 Enable the ERP ring configuration using the erp-ring enable command.
-> erp-ring 1 enable
9 Display the ERP configuration using the show erp command.
-> show erp