OmniSwitch OS6860/OS6900/OS10K Troubleshooting Guide Part No.032996-00 Rev.A
AOS Release 7.X and 8.X January 2015
Alcatel-Lucent Page 10 of 148
Total PS
Chassis/PS Power Type Status Location
-----------+---------+--------+--------+-----------
1/1 150 AC UP Internal
Total 150
sno-lab-r1-6860> show powersupply 1
Module in slot PS-1
Model Name: PS-150AC,
Module Type: 0x6040102,
Description: AC-PS,
Part Number: 903400-90,
Hardware Revision: A04,
Serial Number: 1335000462,
Manufacture Date: Sep 2 2013,
Operational Status: UP,
Power Provision: 150W
Make sure that all the known good power supplies are operational.
3 Verify the CPU utilization.
The CPU utilization of CMM can be viewed by using the command:
LAB-6860> show health
CMM Current 1 Min 1 Hr 1 Day
Resources Avg Avg Avg
----------------------+---------+-------+-------+-------
CPU 7 7 7 7
Memory 61 61 56 56
The above command shows the memory, CPU statistics for current, 1 minimum average, 1 hour average and 1
hour maximum.
Check the threshold in health configuration, using command:
sno-lab-r1-6860> show health configuration
Rx Threshold = 80,
TxRx Threshold = 80,
CPU Threshold = 80,
Memory Threshold = 80,
Sampling Interval (Secs) = 10
All the values should be within the threshold. Any value above the threshold indicates abnormal behavior. The
1 hour average might be high if the switch was booted whithin the last hour but should normalize during the
first hour of operation.
If none of the values are above the threshold, the next step is to attempt to isolate the problem to a particular
NI, using command:
6860-> show health slot 1/1
Slot 1/ 1 Current 1 Min 1 Hr 1 Day
Resources Avg Avg Avg
----------------------+---------+-------+-------+-------
CPU 8 7 7 6
Memory 61 61 59 57
Receive 0 0 0 0
Receive/Transmit 0 0 0 0