Managing Power over Ethernet (PoE) Power over Ethernet Defaults
OmniSwitch 6860 Hardware Users Guide October 2022 page 4-9
changes the priority value of port 6 to the highest priority level of critical. Now that the default value has
been reconfigured, this port should be reserved for those PDs that are mission critical for network opera-
tions.
Setting the Capacitor Detection Method
By default, the capacitor detection method is disabled. To enable it, use the lanpower capacitor-detec-
tion. For example:
-> lanpower slot 3/1 capacitor-detection enable
Note. The capacitive detection method should only be enabled to support legacy IP phones. This feature
is not compatible with IEEE specifications. Please contact your Alcatel-Lucent sales engineer or Customer
Support representative to find out which Alcatel-Lucent IP phones models need capacitive
detection enabled.
Setting Timers and Other User-Defined PoE Power Rules
The lanpower power-rule command allows user to set additional rules for PoE power (e.g., setting PoE to
turn on or off on specific dates or at specific times). Refer to the OmniSwitch AOS CLI Guide for more
information.