EasyManuals Logo

aldes 611242 Installation Guide

aldes 611242
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
611242 - Digital Multifunction Control
Installation guide
Manual 611242 - Installation, R04 1
Important:
This guide and the user guide are available at www.aldes.ca/products/residential/accessories
Model
611242 Digital Multifunction Control
Description
Decora™-style wall mount electronic controller with dehumidistat, compatible with Aldes
HRV and ERV air exchange systems.
Characteristics
Compact and elegant design that fits discreetly in every decor
High-accuracy, fast-response humidity sensor
Liquid-crystal display showing the current humidity level, setpoint, and mode of
operation
4-button keypad to select the mode of operation, the setpoint value, and the fan speed
Blue LED backlight configurable as a night light
Two energy-friendly modes with automatic exchange and exchange-recirculation cycles
Timer-controlled high-speed exchange modes for high occupancy conditions: birthdays, celebrations, etc.
Specifications
Power entry:
22 to 26 VAC, 60 Hz
Maximum load, high-speed control output:
10 Watts maximum (0.42 A @ 24 VAC)
Maximum load, low-speed control output:
0.24 Watts maximum (0.01 A @ 24 VAC)
Timer input:
Compatible with Aldes Timer 611228
Operating temperature range:
0 to 50 °C (32 to 122 °F)
Storage temperature range:
-20 to 50 °C (-4 to 122 °F)
Dimensions:
Height 102.7 mm, Width 44.3 mm, Depth 28.5 mm
(4.04" x 1.74" x 1.12")
Precautions and warnings
Always switch off the power supply to the air exchange system during the installation of the control.
Do not install the control on an electrical junction box embedding wires at 120 / 240VAC or else. The
multifunction control must be installed on a dedicated electrical junction box or wall opening.
First check if the control is compatible with your air exchange system before connecting and powering-up the
unit. Non-compatibility could result in a dysfunction or breakage, or could damage the air exchange system.
Connect the multifunction control in compliance with the instructions provided in this document. An improper
connection could result in a dysfunction or could damage the device.
Do not spray any type of liquid nor apply a soaked cloth on the device. Any infiltration in the device can corrupt
its operation momentarily or permanently.
Always service your air exchange system as prescribed in its operating manual to prevent any loss of
performance.
Install the multifunction control on an internal wall for optimal reading of the ambient relative humidity.