USER MANUAL
In spaces with combustion devices
InstalltheCOdetectorat1to3metersawayfromcombustiondevices,withintheairow
from the combustion device.
• I
nstall the CO detector way from of roof ridges, corners. arched ceilings or front roofs
.
In the case of smaller spaces (<4m³), the detector should be installed outside these spaces.
Install the CO detector 60 centimeters from surrounding walls and ceilings.
Installation on both walls and ceiling is possible in rooms with a combustion device.