WARNING
Use proper protective equipment, such as safety boots, safety gloves and
eye protection, when using the cleaning agents.
WARNING
Corrosive cleaning liquids. Can cause serious injuries to skin and eyes!
6.3.1 Deposits removable with water and brush
Plates do not need to be removed from the heat exchanger during cleaning.
1
Start cleaning when the heating surface is still
wet and the plates are hanging in the frame.
2
Remove deposits using a soft brush and
running water.
3
Rinse with water using a high pressure hose.
6.3.2 Deposits not removable with water and brush
Plates must be removed from the heat exchanger during cleaning. For a choice of cleaning agents,
refer to Cleaning liquids on page 32.
1
Brush with cleaning agent.
200000547-4-EN-GB 37
Maintenance 6 EN