EasyManua.ls Logo

Alicat M Series - Gas Select

Alicat M Series
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
To send a Tare command via RS-232 / RS-485, enter the following strings:
In Streaming Mode: $$V<Enter>
In Polling Mode: Address$$V<Enter> (e.g. B$$V<Enter>)
Gas Select – The selected gas can be changed via RS-232 / RS-485 input. To change the selected
gas, enter the following commands:
In Streaming Mode: $$#<Enter>
In Polling Mode: Address$$#<Enter> (e.g. B$$#<Enter>)
Where # is the number of the gas selected from the table below. Note that this also corresponds to the
gas select menu on the ow meter screen:
# GAS
0 Air Air
1 Argon Ar
2 Methane CH4
3 Carbon Monoxide CO
4 Carbon Dioxide CO2
5 Ethane C2H6
6 Hydrogen H2
7 Helium He
8 Nitrogen N2
9 Nitrous Oxide N2O
10 Neon Ne
11 Oxygen O2
12 Propane C3H8
13 normal-Butane n-C4H10
14 Acetylene C2H2
15 Ethylene C2H4
16 iso-Butane i-C2H10
17 Krypton Kr
18 Xenon Xe
19 Sulfur Hexa uoride SF6
20
75% Argon / 25% CO2
C-25
21
90% Argon / 10% CO2
C-10
22
92% Argon / 8% CO2
C-8
23
98% Argon / 2% CO2
C-2
24
75% CO2 / 25% Argon
C-75
25
75% Argon / 25% Helium
A-75
26
75% Helium / 25% Argon
A-25
27
90% Helium / 7.5% Argon / 2.5% CO2
(Praxair - Helistar® A1025)
A1025
28
90% Argon / 8% CO2 / 2% Oxygen
(Praxair - Stargon® CS)
Star29
29
95% Argon / 5% Methane
P-5
For example, to select Propane, enter: $$12<Enter>