Appendix
A
Publication
65566.5.1 - October 1996
Description of Operating
Modes
You can select any one of the following operating modes with the
mode selector switch:
• Off
• Remote
• Inch
• Micro-inch
• Single stroke
• Continuous stroking
Off
When an operator selects OFF, the control system is designed to turn
off all outputs to press valves.
Remote Mode
When an operator switches the mode selector switch to Remote
mode, the control system can operate in the following modes when
enabled by the corresponding mode-select command bit in your
ladder logic (PF15):
• remote inch mode B151/10
• remote single-stroke mode B151/13
• remote continuous mode B151/14
• remote micro-inch mode B151/24
• remote automatic single stroke B151/26
For examples of enabling remote modes, refer to ladder logic in
chapter 4, Figures 4.8, 4.11, 4.17, 4.18, 4.19, 4.20.
Next, we describe the remaining operating modes with flow charts.
Operating Modes of the
Clutch/Brake Controller