Description of Operating ModesA–8
Publication
65566.5.1 - October 1996
Figure A.5
Typical
Operational Sequence for Arm Continuous in Continuous Mode
Have you released a Run button,
or has a stop condition occurred?
Both processors deenergize their
outputs to stop the press.
Both processors
energized their outputs.
Has the press reached
the upstroke zone?
Have you released
all Run buttons?
Have you pressed the
Arm Continuous button?
Go to R6.
(Figure A.7)
NOTE: Releasing a Run button during first downstroke stops the press. If the slide has not entered
the upstroke zone, you can resume downstroke within 5 seconds of pressing the Arm Continuous
button. (The Arm Continuous preset could be less than 5 seconds.) After 5 seconds (the press is
stopped), you must restart continuous mode with the arming sequence.
R4
No
Yes
Yes
Have you pressed
all Run buttons?
Yes
Has the Arm Continuous
timer timed out?
No
No
Yes
No
No
Yes
No
Yes