Rockwell Automation Publication 1783-UM010C-EN-P - June 2019 67
Configure the Security Appliance Chapter 3
Configure SPAN Port Monitoring Settings
This section only applies to SPAN Port mode configuration only.
1. Run PuTTY and connect to the serial port of the device.
2. Click Open to start a command-line session.
3. At command line, press Enter.
4. Type: stratix5950> enable
5. Press Enter.
6. Enter the ASA password that was set in the Startup Wizard and press
Enter.
7. #configure terminal
8. interface BVI1
9. no ip address
10. interface GigabitEthernet1/1
11. no nameif
12. traffic-forward sfr monitor-only
13. no shutdown
14. no bridge-group 1
15. write
16. Physically connect port 1 of the device to another switch that has Port
Mirroring (SPAN port) enabled for that port.
TIP This procedure is from Cisco, for more information go to http://
www.cisco.com/c/en/us/td/docs/security/asa/asa96/configuration/
firewall/asa-96-firewall-config/access-sfr.html
TIP You can ignore any warnings about forwarded traffic being for
demonstration purposes only, which is a supported production mode.