EasyManua.ls Logo

Allen-Bradley Ultra1500 2092-DA1 - Page 176

Allen-Bradley Ultra1500 2092-DA1
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Publication 2092-UM001D-EN-P — July 2005
D-12 Ultra1500 Operator Interface
Pr-0.04 Inertia Ratio
Pr-0.05 Input Signal Assignment - Group 1
Pr-0.06 Input Signal Assignment - Group 2
0x1 Slowest
0x2 Slower
0x3 Slow
0x4 Medium-Slow
0x5 Medium
0x6 Medium-Fast
0x7 Fast
0x8 Faster
0x9 Fastest
Default: 0
Units:
Range: 0 to 6000
Default: 0
Units: (Load Inertia / Motor Inertia) * 100
Ultraware Link: Inertia Ratio
Range for all digits: 0 to 8
Value Description
0 Input Signal OFF
1 to 7
Input signal assigned to
hardware inputs 1 through 7
8 Input Signal ON
Data Size: 4 digits
Digits: Digit Description Default
0 Drive Enable 0x1
1 Overtravel – Positive 0x8
2 Overtravel – Negative 0x8
3 Integrator Inhibit 0x0
Applicable Operating Mode All
Range for all digits: 0 to 8
Value Description
0 Input Signal OFF
1 to 7
Input signal assigned to
hardware inputs 1 through 7

Table of Contents