EasyManua.ls Logo

Allen-Bradley Ultra1500 2092-DA1 - Page 188

Allen-Bradley Ultra1500 2092-DA1
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Publication 2092-UM001D-EN-P — July 2005
D-24 Ultra1500 Operator Interface
Pr-4.01 Current Limits: Positive Internal
Pr-4.02 Current Limits: Negative Internal
Pr-4.03 Current Limits: Positive External
Pr-4.04 Current Limits: Negative External
Pr-4.05 Stopping Functions: Maximum Stopping Current
Units: % of rated continuous current/V*10
Applicable Operating Mode: Analog Current, Dual Current
Ultraware Link: Current Scale
Range: 0 to 500
Default: 500
Units: % of motor rated continuous current
Applicable Operating Mode: All
Ultraware Link: Current Limits: Positive Internal
Range: 0 to 500
Default: 500
Units: % of motor rated continuous current
Applicable Operating Mode: All
Ultraware Link: Current Limits: Negative Internal
Range: 0 to 500
Default: 100
Units: % of motor rated continuous current
Applicable Operating Mode: All
Ultraware Link: Current Limits: Positive External
Range: 0 to 500
Default: 100
Units: % of motor rated continuous current
Applicable Operating Mode: All
Ultraware Link: Current Limits: Negative External
Range: 0 to 500
Default: 500
Units: % of motor rated continuous current
Applicable Operating Mode: All
Ultraware Link: Stopping Functions: Maximum Stopping Current

Table of Contents