EasyManua.ls Logo

Allen-Bradley Ultra1500 2092-DA1 - Input Power Connectors; Main Power - L1, L2, and L3; Power Connections

Allen-Bradley Ultra1500 2092-DA1
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Publication 2092-UM001D-EN-P — July 2005
2-24 Ultra1500 Connector Data
Figure 2.24
Simplified Ultra1500 Internal Power Circuitry
Input Power Connectors
The following power connections are made to an Ultra1500 drive through a six
position terminal connector.
Main Power – L1, L2, and L3
L1 and L2 are single-phase main AC power input connections for the
2092-DA1, 2092-DA2, and 2092 -DA3 drives. L1, L2, and L3 are three-phase
main AC power input connections for the 2092-DA4 and 2092 -DA5.
Note: The L3 terminal is not used with the 2092-DA1, 2092-DA2, and
2092-DA3 models, as they require single-phase input power.
Diode
Bridge
Integrated
Power
Module
L1
L2
L3
U
V
W
Soft-Start
Relay
Dynamic
Brake Relay
NTC
DC
BUS
+
-
C
BUS
P2
P1
N
B1
B2
Shunt
Circuitry
Dynamic Brake Diodes
Switch
Mode
Power
Supply
L1C
L2C
+5V
+12V
-12V
IPM
Power for
Control
Circuitry
Diode
Bridge
Note: DC Bus Negative is labelled N on the drive cover, but DC- on the removable connector.
ATTENTION
!
The main AC power inputs should not be removed and
re-applied at a rate exceeding once every 2 minutes. Ensure
that your control timing guarantees this minimum period to
avoid damaging the drive.

Table of Contents