Ultra1500 Application Examples 5-9
10. The Online Command – Apply Test window opens. When the test
completes, the Command Status changes from Executing to Command
Complete.
11. Select OK.
12. Select the Tune tab.
13. Enter values for Travel Limit and Speed. In this example the Travel Limit
is 5 revs and the Speed is set to 5 revs/s.
Note: Actual values (Revs) depend on your application.