Dryer Heater Assembly or Burner Shuts Off Prematurely
Is exhaust system
improper or
inadequate?
Is weather hood
flapper restricted?
No
Refer to Installation
Instructions
(supplied with unit)
for exhaust
requirements.
Yes
Gas Models: Is gas
supply insufficient?
No
Refer to Installation
Instructions
(supplied with unit)
for exhaust
requirements.
Yes
Gas Models: Is dryer
properly equipped for
type of gas used?
No
Check main gas line
shut-off valve. Open
partially closed gas
shut-off valve or
correct low pressure.
Yes
Gas Models: Is burner
flame improperly
adjusted?
Yes
Refer to "Gas Burner
Conversion
Procedures" supplied
in gas burner
conversion kit.
No
Cycling off on limit
thermostat?
No
Adjust flame. Refer
to Adjustments
section.
Yes
Gas Models: Is sensor
contact closing
No
Momentarily connect a
jumper wire across
thermostat terminals.
If heater element
heats or burner
ignites when jumper
wire is connected,
refer to next
flowchart.
Yes
Is cycling thermostat
inoperative?
No
Replace sensor or
adjust burner flame
(refer to Adjustments
section).
Yes
Is timer/electronic
control inoperative?
No
Test thermostat and
replace if
inoperative.
Yes
Is wiring broken,
loose or incorrect?
No
Test timer/
electronic control
and replace if
inoperative.
Yes
Refer to wiring
diagram.
Yes
Troubleshooting Flowcharts
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
25 Part No. D515517ENR3

Table of Contents