Water Connection Requirements
NOTE: Read Important Safety Instruction first.
Models manufactured through April, 2017
CHM2503N_SVG
1 2
NOTE: North American Models: Water inlet hose with
notches should be connected to the water supply
faucet, while the side of the water inlet hose without
notches should be connected to the water inlet
valves.
1. Water inlet valve connection (hose connection without
notch)
2. Water supply faucet connection (hose connection with
notch)
Figure 16
Models manufactured starting May, 2017
C-CZW2N
1
2
3
4
NOTE: North American Models: Install threaded re-
duction pieces together with sealant on all inlet
valves. The filling hose end piece with an internal fil-
ter must be connected to the water inlet tap. The
second end of the hose must be connected to a re-
duction piece.
1. Hose
2. Reduction
3. Seal
4. Valve
Figure 17
NOTE: Models outside of North America: For 7.5 kg / 20
lb. / 75 L,
10.5 kg / 25 lb. / 105 L, 13.5 kg / 30 lb. / 135 L,
18 kg / 40 lb. / 180 L and 24 kg / 55 lb. / 240 L Models, to
connect cold water, use a hose with plastic elbow. To
connect hot water, use a hose with metal elbow.
Do not re-use water hoses; only use new water hoses.
The appliance has been designed with a built-in "AB" airgap sys-
tem according to EN1717. Nevertheless, when potable water will
be connected to the appliance, a local compliant double check
valve or some other no less effective device providing backflow
prevention protection to at least fluid category three shall be fit-
ted at the point of connections between the water supply and the
appliance.
To comply with UK water regulations a WRAS or NSF Reg 4 or
KiwaUK Reg 4 compliant double check valves must be used. Re-
fer to Figure 20
To comply with the Plumbing Code of Australia regulations
accordance to standard WMTS-101 an approved
dual check valve backflow prevention device with the watermark
must be fitted at the point of connection between the supply and
the fitting. Refer to Figure 20
All intake connections to the machine are to be fitted with man-
ual shut-off valves and filters, to facilitate installation and servic-
ing.
NOTE: In case it is necessary to disconnect the hot wa-
ter hose from the washer, isolate the hot water hose
from the hot water supply and wait sufficient time to al-
low to cooldown the water temperature and connection
hose. Then turn the connection nut slowly loose until
water starts dripping. Wait until dripping stops, then
disconnect further.
All water connectors present on the machine must be connected
or the wash program will not function correctly. Refer to Table 12
for possible connection options, which will depend on the water
types to be connected to the machine, which can be found by
checking the machine plates.