Three-Phase Connections
Three Phase Connection - North American Models
Connect the electrical service's wires to the machine's electrical
connection terminal as shown.
Electrical Service Wire
Machine's Electrical
Connection Terminal
L1 L1
L2 L2
L3 L3
PE PE (Ground)
Table 18
North American Models with Three-Phase Connec-
tion
L1
L2
PE L1L2
L3
PE
L3
CHM2498N_SVG
Figure 31
Three Phase Connection - Models Outside of North
America
Connect the electrical service's wires to the machine's electrical
connection terminal as shown.
Electrical Service Wire
Machine's Electrical
Connection Terminal
U U
V V
W W
Table 19 continues...
Electrical Service Wire
Machine's Electrical
Connection Terminal
PE PE (Ground)
Table 19
Electrical Connection Terminal Block
Figure 32
Models Outside of North America with Three-Phase
Connection
U
V
PE UV
W
W
PE
N
N
CHM2502N_SVG
Figure 33
Phase Adder
Machines can be converted for lower voltage operation and/or 50
Hz operation. Refer to conversion label by serial plate for details.
IMPORTANT: Do not use a phase adder on any ma-
chine.
Voltage Settings
When a transformer is provided (control or step down transform-
er), it is set to the highest voltage of the range at the manufactur-
ing facility
. If, at installation, the nominal supply voltage is lower,
the appropriate voltage terminal on the transformer must be se-
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
53 Part No. D1599ENR16