10.5 kg / 25 lb. / 105 L Models
Voltage (V)
Frequency (Hz)
Phase
Wire
Standard Electric Heat
Total Power (kW)
Full Load Amps (A)
Fuse (A)
Total Power (kW)
Full Load Amps
(Electric Heating kW)
Fuse (A)
120 60 1 2 0.65 11.7 16 N/A N/A N/A
200-240 50/60 1 2 (L1, L2,
or L1, N)
0.65 6.3 10 3.5 17.5 (3) 20
5.1 25 (4.6) 32
200-240 50/60 3 3 (L1, L2,
L3)
0.65 6.3 10 6.6 20.1 (6) 25
9.6 27.6 (9) 32
12.6 35.2 (12) 40
380-415
+ N
50/60 3 4 (L1, L2,
L3, N)
0.65 6.3 10 6.6 12.5 (6) 16
9.6 17.5 (9) 20
12.6 22.4 (12) 25
380-415 50/60 3 3 (L1, L2,
L3)
0.65 3.7 10 6.6 12.6 (6) 16
9.6 17 (9) 20
12.6 21.3 (12) 25
440-480 50/60 3 3 (L1, L2,
L3)
0.65 3.7 10 7.6 12.3 (7) 16
9.6 15.7 (9) 16
12.6 20 (12) 25
Table 21