24 kg / 55 lb. / 240 L Models (200G)
Code
Voltage
(V)
Frequen-
cy (Hz) Phase Wire
Full Load
Amps (A)
Circuit
Breaker
CSA (A)
AWG (mm
2
)
X and Z 208-240 60 1 2 (L1, L2 or
L1, N)
9.2 15 14 (2.5)
Table 35
28 kg / 70 lb. / 280 L Models (200G)
Code
Voltage
(V)
Frequen-
cy (Hz) Phase Wire
Full Load
Amps (A)
Circuit
Breaker
CSA (A)
AWG (mm
2
)
X and Z 208-240 60 1 2 (L1, L2 or
L1, N)
9.9 15 14 (2.5)
Table 36
35 kg / 80 lb. / 332 L Models
Code
Voltage
(V)
Frequen-
cy (Hz) Phase Wire
Full Load
Amps (A)
Circuit
Breaker
CSA (A)
AWG (mm
2
)
X and Z 208-240 60 1 2 (L1, L2 or
L1, N)
16 20 14 (2.5)
7 440-480 60 3 3 (L1, L2, L3) 8.2 15 14 (2.5)
Table 37
52 kg / 120 lb. / 520 L Models
Code
Voltage
(V)
Frequen-
cy (Hz) Phase Wire
Full Load
Amps (A)
Circuit
Breaker
CSA (A)
AWG (mm
2
)
M 208-240 60 3 3 (L1, L2, L3) 16 20 14 (2.5)
7 440-480 60 3 3 (L1, L2, L3) 9.6 15 14 (2.5)
Table 38
Steam Requirements (Steam Heat
Option Only)
NOTE: Read Important Safety Instruction first.
In case it is necessary to disconnect the steam hose from the
washer, isolate the steam hose from the steam supply and wait
suf
ficient time (min 1h) to allow to cooldown the steam system.
Then turn the connection nut slowly loose until some pressure es-
capes. Wait until the escape stops, then disconnect further.
For machines equipped with optional steam heat, install piping in
accordance with approved commercial steam practices. Steam re-
quirements are shown in Table 39 .