check with your liquid soap supplier whether the liquid soap is
harmless and inert to PP and PVC material in order to avoid dam-
age to machine.
IMPORTANT:
Failure to follow these instructions could
damage the machine and void the warranty.
Connection of External Liquid Supplies
NOTE: Read Important Safety Instruction first.
1. Facing the rear of the machine, locate the eight (8) 5/16 inch
[8 mm] supply hose connections found on the left-hand side
of the valve panel. Refer to Figure 35
.
NOTE: Recommended setting of the pump's flow
rate is 60 to 100 liters per hour.
Valve Panel-Rear View
CZW241N
1. External Supply Hose Connections
2. Cable Bushing
3. Control Signals Terminal Box
Figure 35
2. Drill through the eight (8) plastic holes on the valve panel for
the external supply hoses as needed.
NOTE: On the valve panel by the external supply
hose connections are three (3) connections of 1/2
in. 12 mm that are to be used only for entering dilu-
ted soap. To use, drill a 7/16 inch 1
1.5 mm hole only
in connections that will be used.
3. Remove plastic debris.
4. Attach the external supply hoses to the ports at each of the
drilled holes.
5. Secure with proper clamps.
IMPORTANT: Check that the hose connections are tight
(check the clamps). Any chemical leakage may cause
serious damage to the washer. If one of the connec-
tions is open, close and secure the opening with an ap-
propriate cover.
NOTE: Do not attempt to make chemical injection sup-
ply pump electrical connections to points other than
those provided specifically for that purpose by the fac-
tory.
Electrical Connection of External
Liquid Soap Supply System
NOTE: Find the connection on the wiring diagram.
The power supply of the external liquid soap supply system has
to be connected to an external electrical source. Only authorized
workers with valid qualifications must execute the electrical con-
nection on the machine according to valid local standards.
The electric connection for supply control signals (if used) is
available on the rear panel. Refer to Figure 35
. At the terminal
box, there is a label for electric connection.
Maximum current for control circuits of pump must be limited to
100mA. Lead the cable for connection of pump control signals
through the plastic cable bushing. After connection of conductors
to the respective positions of the connector on the Liquid Soap
Extension Board, fix up the cable by tightening the cable bushing
against disconnections and close the box with the cover. For de-
tails about liquid soap supply system programming, refer to Pro-
gramming Manual.
External Wait Control
NOTE: Find the connection on the wiring diagram.
This function can be activated by an external contact which is
connected between the pins and . Refer to Figure 35
. Such
connection is possible only with machines which had been or-
dered with the "Heating Delay / Waiting for Detergent" option.
Chemical Soap Supply System
NOTE: Read Important Safety Instruction first.
Undiluted chemical dripping can damage the washerextractor.
Therefore, all chemical supply dispenser pumps should be moun-
ted below the washerextractor
s injection point. All dispenser
tubing should also run below the injection point. Loops do not
prevent drips if these instructions are not followed. Failure to fol-
low these instructions could damage the machine and void the
warranty. Figure 36 shows a typical chemical injection supply
system.