1. Washer Motor Circuit
2. Troubleshooting Knocking Noise
If a frontload washer produces a noise similar to a
knock on a door, it might be due to a flat spot on
the belt. The knocking sound is made when the flat
spot hits the pulley. The knocking may occur
during a pulse spin and fade after reaching a
higher RPM.
To correct this condition, replace the belt.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect all electric power to the machine and accessories before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start machine with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
Windings
Tach. Circuit
White
Gray
Red
Red
Red
5
43
21
Resistance Values:
Tachometer Circuit:
Terminals 45
Approx. 115 ohms
Windings:
Terminals 1–2, 2–3, 1-3
Approx. 4.5 ohms