46 801683
Section 3 Troubleshooting (NetMaster and MDC Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
19. WASHER WILL NOT FILL (MACHINE EMPTY, NO E:SP ON DISPLAY)
Washer Will Not Fill
(Machine empty, No E:SP on display)
Is there
220-240 VAC (or
120 VAC)* across terminals
"H1-1" and "H9-4" on
the motor
control?
(1)
(2)
Yes
Yes
Correct wiring from
pressure switch or
replace pressure
switch.
Is there
220-240 VAC
(or 120 VAC)* across
terminals "H9-6" to "H1-1"
(hot) and "H9-3"
to "H1-1"
(cold)?
Yes
No
No
Replace motor
control board.
Replace mixing
valve.
(3)
Is there
220-240 VAC
(or 120 VAC)* across
mixing valve
solenoid(s)?
No
Replace motor
control.
Is the door
locked?
Refer to
Washer Will Not Start -
E:dL on display
section
No
Yes
FLW1698S
*Refer to machine serial plate for correct voltage.
1
2
3

Table of Contents