To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3. MOTOR OVERLOAD PROTECTOR CYCLES REPEATEDLY
4. MOTOR RUNS BUT CYLINDER DOES NOT TURN
5. MOTOR DOES NOT STOP
POSSIBLE CAUSE TO CORRECT
Incorrect voltage • Refer to Installation Instructions (supplied with tumble
dryer) for electrical requirements.
Clothes load is too large. • Remove part of load.
Clothes cylinder is binding. • Check cylinder for binding.
Inadequate wiring. • Check with local power company to ensure that wiring is
adequate.
Inadequate make-up air. • Refer to Installation Instructions (supplied with tumble
dryer) for make-up air requirements.
Lint buildup around tumble dryer, poor
housekeeping.
• Clean lint accumulation on and around the motors.
Broken, loose or incorrect wiring. • Refer to wiring diagram.
POSSIBLE CAUSE TO CORRECT
Broken cylinder belt. • Replace cylinder belt.
Cylinder is binding. • Check cylinder for binding.
POSSIBLE CAUSE TO CORRECT
Inoperative door switch or lint drawer switch. • Test switches and replace if inoperative.
Inoperative coin drop. • Test coin drop and replace if inoperative.
Incorrect wiring. • Refer to wiring diagram.
Electronic control inoperative. • Replace electronic control.