70143101 25
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
23. JUNCTION BOX/CONTROL BOX
STACKED TUMBLE DRYER
a. Remove four screws holding junction box
cover in place. Refer to Figure 28.
b. Remove junction box cover.
STAND ALONE TUMBLE DRYER
a. Remove four screws holding control tray cover
in place. Refer to Figure 29.
b. Remove control tray cover.
24. FUSE AND FUSE HOLDER ASSEMBLY
Refer to Figures 13, 14 and 15.
NOTE: Fuse holder is located in the junction box at
the rear of the machine. There is a fuse access door
in the junction box cover for changing fuses.
a. Remove junction box cover. Refer to
Paragraph 23.
b. Turn fuse cap counterclockwise to remove fuse.
c. Disconnect wires from fuse holder.
NOTE: Refer to wiring diagram when rewiring
fuse.
d. Remove retaining nut holding fuse holder
assembly to junction box and remove assembly.
Figure 13
Figure 14
Figure 15
T259SE1A
Fuse
Cap
Fuse
Holder
Retaining
Nut
Fuse