EasyManua.ls Logo

Alliance Laundry Systems ST0300DRG - Cylinder Rollers; Roller Shaft

Alliance Laundry Systems ST0300DRG
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26 70143101
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
25. CYLINDER ROLLERS
Refer to Figure 16.
a. Unlock and remove lint drawer/panel. Refer to
Figure 11.
b. Remove control panel and control assembly.
c. Remove front panel.
d. Remove nuts from end of roller shafts. Refer to
Figure 16.
e. Lift cylinder slightly and remove rollers from
shafts. Refer to Figure 16.
26. ROLLER SHAFT
Refer to Figure 16.
a. Unlock and remove lint drawer/panel. Refer to
Figure 11.
b. Remove front panel. Refer to Figures 3 and 4.
c. Remove cylinder rollers. Refer to
Paragraph 25.
d. Remove nuts from front and back of roller
shaft.
e. Slide shaft back out of air duct roller support
assembly.
Figure 16
T262SE3A
Cylinder
Roller
Roller
Shaft
Nut
Nut
Air Duct
Roller Support
Assembly

Table of Contents

Related product manuals