32 70143101
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
31. AIRFLOW SWITCH
Refer to Figure 22.
a. Remove fan motor assembly. (Stacked Tumble
Dryers only). Refer to Paragraph 46.
b. Remove two screws on air flow switch guard
and remove guard.
c. Disconnect wires from switch.
NOTE: Refer to wiring diagram when rewiring
switch.
d. Remove two screws and one speed nut holding
switch to mounting bracket.
Stacked Tumble Dryer Stand Alone Tumble Dryer
Figure 22
T264SE1A
GUARD
SCREW
WIRES
SPEED
NUT
AIRFLOW
SWITCH
MOUNTING
BRACKET
T265SE1A
GUARD
AIRFLOW
SWITCH
MOUNTING
BRACKET
SCREW
SPEED
NUT
WIRES