Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
32. STOVE HIGH LIMIT THERMOSTAT
Refer to Figure 23.
a. Remove cover screws holding gas valve cover
to stove and remove cover.
b. Disconnect wires from stove limit thermostat.
NOTE: Refer to wiring diagram when rewiring
thermostat.
c. Remove screws holding stove limit thermostat
to stove.
Stacked Tumble Dryer
Stand Alone Tumble Dryer
Figure 23
60%
TMB34S
STOVE LIMIT
THERMOSTAT
COVER
SCREW
GAS VALVE
COVER
THERMOSTAT
ATTACHING
SCREW
75%
TMB35S
STOVE
LIMIT
THERMOSTAT
THERMOSTAT
ATTACHING
SCREW
STOVE