70143101 37
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
37. ELECTRONIC IGNITION CONTROL
STACKED TUMBLE DRYER
Refer to Figure 28.
a. Remove screws holding rear control box cover
to control box and remove cover.
b. Disconnect wire harness.
c. Remove high voltage lead.
d. Remove screws holding ignition control to
control box and remove ignition control.
Figure 28
T274SE3A
TRANSFORMER
HIGH
VOLTAGE
LEAD
ELECTRONIC
IGNITION
CONTROL
JUNCTION
BOX
JUNCTION BOX
COVER SCREW
JUNCTION
BOX COVER