40 70143101
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39. CABINET THERMOSTAT
STACKED TUMBLE DRYER
Refer to Figure 30.
a. Remove screws holding guard to blower
housing.
b. Disconnect wires to cabinet thermostat.
c. Remove screws holding thermostat to blower
housing and remove cabinet thermostat.
STAND ALONE TUMBLE DRYER
Refer to Figure 31.
a. Remove screws holding guard to tumble dryer
and remove guard.
b. Disconnect wires from cabinet thermostat.
c. Remove screws holding cabinet thermostat to
cabinet and remove cabinet thermostat.
NOTE: Thermistor and cabinet thermostat are
located inside cabinet in models after Serial No.
9807017296. Refer to Figure 31.
Figure 31
T269SE3A
THERMISTOR
CABINET
THERMOSTAT
CABINET
GUARD
FAN
MOTOR
CABINET
THERMOSTAT
(NEW LOCATION)
VIEW FROM
INSIDE TUMBLE
DRYER
THERMISTOR
(NEW LOCATION)
DRIVE
ACCESS