42 70143101
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
41. CONTACTORS AND TERMINAL BLOCK
(Electric Models)
Refer to Figure 33.
a. Remove screws holding cover and remove
cover.
b. Loosen terminal screws and remove all wires
from contactor.
c. Disconnect wires from contactor.
d. Remove four contactor attaching screws and
remove contactor.
NOTE: Refer to wiring diagram when rewiring
contactor.
Stacked Tumble Dryer
Stand Alone Tumble Dryer
Figure 33
T425PE3G
Contactor
Contactor
Attaching
Screw
Terminal
Block
Drive
Access
Cover
T406PE3B
CONTACTOR
TERMINAL
BLOCK
SCREW
CONTACTOR
ATTACHING
SCREW
DRIVE
ACCESS
COVER