EasyManua.ls Logo

Alliance Laundry Systems ST0300DRG - Steam Coil; Steam Solenoid Valve

Alliance Laundry Systems ST0300DRG
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70143101 43
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
42. STEAM COIL
Refer to Figure 34.
a. Disconnect pipes to steam coils.
b. Remove bottom screws holding steam coils to
back of tumble dryer cabinet.
c. Support steam coils and remove top screws,
then remove steam coils.
43. STEAM SOLENOID VALVE
Refer to Figure 35.
a. Disconnect pipes.
b. Disconnect wires.
c. Remove valve by turning valve
counterclockwise.
Figure 34
Allow steam coils and valve to cool down
before attempting any service procedures.
W249
CAUTION
TMB1755S
ATTACHING
SCREW
STEAM
COIL
Figure 35
Allow steam coils and valve to cool down
before attempting any service procedures.
W249
CAUTION
T449PE1A
STEAM
SOLENOID
VALVE

Table of Contents