Alliance Laundry Systems ST0300DRG - Fan Motor Assembly

Alliance Laundry Systems ST0300DRG
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70143101 47
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
46. FAN MOTOR ASSEMBLY
STACKED TUMBLE DRYER
Refer to Figure 40.
a. Remove cabinet limit cover and harness. Refer
to Figure 30.
b. Unscrew thermistor.
NOTE: Do not turn thermistor by spade terminals.
IMPORTANT: Before attempting to service fan,
always remove thermistor to prevent damage.
c. Disconnect wire harness to fan motor.
d. Remove ten screws holding fan motor
assembly to blower housing. Refer to
Figure 38.
e. Tilt fan motor forward until it clears stove.
f. Remove palnut and jamnut holding fan to
motor shaft and remove fan from motor shaft.
g. Remove four bolts holding fan motor to
mounting plate and remove motor.
Figure 40
T307SE1A
Fan
Motor
Motor
Shaft
Fan
Mounting
Plate
Thermistor
Palnut
Jamnut