The IR Communications Menu displays while the control is com-
municating with a PDA. The control will jump back to the previ-
ous page when the communication is complete.
IR Communications Error Menu
Invalid Data
PHM1004R_SVG1
1
1. Invalid Data
Figure 4
The IR Communications Error Menu displays after the control
had an error communicating with a PDA. The control will return
to previous page after 3 seconds.
Restore to Factory Defaults
When the user selects Restore All Cycles And Global Settings To
Factory-Defaults, the control resets all of the default values. The
control also resets Machine Cycles #1 through #41. The control
will also reset the following to factory-defaults:
Default Global Settings
Language = English
Ignition Retries = 3
Temperature Units = Fahrenheit (°F)
High (H) Temperature = 190 (°F)
Medium (M) Temperature = 160 (°F)
Low (L) Temperature = 140 (°F)
Very Low (VL) Temperature = 120 (°F)
Cool Down Temperature = 100 (°F)
Cool Down Time = 2 (minutes)
Rapid Advance = Disabled
Multi-Segment Cycles = Disabled
LCD Backlight ON/OFF = On
Banner # 1 = Blank
Banner # 2 = Blank
Daylight Saving = Enabled
Key Pad Audio = Enabled
End of Cycle Audio = Low (5 seconds)
End of Cycle External Signal = Enabled (5 seconds)
Clean Lint Screen Reminder = Off
Display Limit Errors = Disabled
Manual Diagnostics = Enabled (accessable via PC and PDA on-
ly)
*Manual Programming = Enabled (accessable via PC and PDA
only)
**Reverse Cylinder Rotate T
ime = 30 (seconds)
**Reverse Cylinder Stop Time = 6 (seconds)
**Advanced Reversing = OFF
***Advanced Options for Moisture Dry = Disabled
***Display Moisture Sensor Error = Disabled
*If manual programming is disabled, programming changes to
UniLinc can only be made with an external communication de-
vice. Refer to UniLinc PC and PDA Application User Instruc-
tions.
**Only available on units equipped with reversing feature.
***Only available on units equipped with moisture sensing fea-
ture.
Refer to Factory Defaults Menu section for information on Re-
storing Factory Defaults.
Entering Program Mode
Press and hold , then , then to enter the Sys-
tem Menu. Select Program to enter programming options.
Preliminary Information
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
9