SHOW SYSTEM ENVIRONMENT
Syntax
show system environment
Parameters
None
Mode
Privileged Exec mode
Description
Use this command to display the environmental information for the switch.
Figure 30 shows an example of the information that the command
displays.
Figure 30. SHOW SYSTEM ENVIRONMENT Command
The columns in the display are described here:
Table 7. SHOW SYSTEM ENVIRONMENT Command
Parameter Description
Switch Model Indicates a model name of the switch.
ID Indicates the ID number of an item.
Sensor (Units) Indicates an item on the switch, such as
temperature, fan, or power supply unit
(PSU).
Environment Monitoring Status
--------------------------------------------------------
Switch Model: AT-9000/28POE
--------------------------------------------------------
ID Sensor (Units) Reading Status
--------------------------------------------------------
0 Temp (Degrees C) 37 Normal
1 Fan 1 (RPM) 3467 Normal
2 PSU 1 On Normal
3 PSU 2 Off Off
--------------------------------------------------------