Chapter 12: Power Over Ethernet Commands
262
NO POWER-INLINE PRIORITY
Syntax
no power-inline priority
Parameters
None
Mode
Port Interface mode
Description
Use this command to restore the default Low priority setting to the ports.
Confirmation Commands
“SHOW POWER-INLINE” on page 274
“SHOW POWER-INLINE INTERFACE” on page 279
“SHOW POWER-INLINE INTERFACE DETAIL” on page 280
Example
This example restores the default Low priority level to port 20:
awplus> enable
awplus# configure terminal
awplus(config)# interface port1.0.20
awplus(config-if)# no power-inline priority