AT-GS900M Series Command Reference
Section III: Layer 2 Switching 357
day_list
The options are mon, tue, wed, thu, fri, sat, sun, weekday,
weekend, or any combination. The weekday is mon, tue, wed, thu,
and fri. The weeekend is san and sun. To specify multiple options,
use comma (,) to separate them.
port_list
Specifies a list of ports. To specify multiple ports, use a comma (,)
to separate them. To specify a range of ports, use a hyphen (-).
all
Specifies all the switch ports.
name
Specifies a trigger name up to 40 alphanumeric characters. Use
double quotes (“”) to specify a space.
poetarget
Specifies a type of PD. This parameter is used when the psmode is
set to poeoff.
alliedtelesis-ap
When the PD is a Allied Telesis wireless access point, the link
relay function is enabled. When the trigger becomes effective, the
switch disconnect the link and stops supplying power to the
connected wireless access point. The wireless access point can
disconnect its clients before shutting down.
other
When the PD is other than Allied Telesis access point. When the
trigger becomes effective, the switch stops supplying power to
PDs. This is the default setting.
state
Enables or disables the trigger. The options are enabled and
disabled. By default, the trigger is enabled.
test
Specifies the trigger to the test mode. When the trigger starts, no
action is taken, but log messages are issued. The default setting is
no.
yes, on
The trigger is in the test mode.
no, off
The trigger is not in the test mode.