C613-50105-01 REV C Command Reference for x210 Series 1548
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PING-POLLING COMMANDS
SHOW
PING-POLL
Figure 45-3: Example output from the show ping-poll command
State The current status of the device being polled:
Up The device is reachable.
Down The device is unreachable.
Critical
Up
The device is reachable but recently the polling
instance has not received some ping replies, so the
polled device may be going down.
Critical
Down
The device is unreachable but the polling instance
received a reply to the last ping packet, so the
polled device may be coming back up.
Destinatio
n
The IP address of the polled device, set with the ip (ping-polling)
command.
Ping Poll Configuration
----------------------------------------------------------
Poll 1:
Description : Primary Gateway
Destination IP address : 192.168.0.1
Status : Down
Enabled : Yes
Source IP address : 192.168.0.10
Critical interval : 1
Normal interval : 30
Fail count : 10
Up count : 5
Sample size : 50
Length : 32
Timeout : 1
Debugging : Enabled
Table 47: Parameters in output of the show ping-poll brief command (cont.)
Parameter Meaning