C613-50105-01 REV C Command Reference for x210 Series 300
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
LOGGING COMMANDS
LOG
PERMANENT (FILTER)
Default By default the buffered log has a filter to select messages whose severity level is
notices (5) or higher. This filter may be removed using the no variant of this
command.
Mode Global Configuration
Examples To create a filter to send all messages generated by EPSR that have a severity of
notices or higher to the permanent log use the following commands:
awplus# configure terminal
awplus(config)# log permanent level notices program epsr
To create a filter to send all messages containing the text “Bridging
initialization”, to the permanent log use the following commands:
awplus# configure terminal
awplus(config)# log permanent msgtext Bridging initialization
epsr Ethernet Protection Switched Rings (EPSR)
rmon Remote Monitoring
loopprot Loop Protection
dhcpsn DHCP snooping (DHCPSN)
facility Filter messages by syslog facility.
<facility> Specify one of the following syslog facilities to include messages from:
kern Kernel messages
user Random user-level messages
mail Mail system
daemon System daemons
auth Security/authorization messages
syslog Messages generated internally by syslogd
lpr Line printer subsystem
news Network news subsystem
uucp UUCP subsystem
cron Clock daemon
authpriv Security/authorization messages (private)
ftp FTP daemon
msgtext Select messages containing a certain text string.
<text-
string>
A text string to match (maximum 128 characters). This is case sensitive, and must be the last
text on the command line.
Parameter Description