XS916MX Series Installation Guide for Stand-alone Switches
43
Installing the Switch in an Equipment Rack
You can install one XS916MX series switch in a row of the equipment rack
or two XS916MX series switches in one row of the equipment rack as
shown in Figure 10.
Figure 10. Rack Installation Options for the XS916MXSeries Switch
Installing Two
Switches in One
Row
To install two switches in one row of the equipment rack, use the AT-
BRKT-J15 rack mount kit.
Here are the guidelines:
You must purchase the AT-BRKT-J15 rack mount kit separately.
For the instructions using the AT-BRKT-J15 rack mount kit, see
The AT-x230-10GP, AT-AR3050S, AT-AR4050S, and XS916MX
Series Switches Rack Mount Installation Guide.
Installing a
Switch in One
Row
To install the switch in one row of the equipment rack, you need the
following items:
Rack mount bracket kit, which comes with the switch
Flat-head screwdriver
Cross-head screwdriver
Note
You must provide flat-head and cross-head screwdrivers.
To install the switch in one row of the equipment rack, perform the
following procedures.