C613-50631-01 Rev A Command Reference for IE340 Series 1170
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
OSPF COMMANDS
RESTART
OSPF GRACEFUL
restart ospf graceful
Overview Use this command to force the OSPF process to restart, and optionally set the
grace-period.
Syntax
restart ospf graceful [grace-period <1-1800>]
Default In the AlliedWare Plus™ OSPF implementation, the default OSPF grace-period is
180 seconds.
Mode Privileged Exec
Usage notes After this command is executed, the OSPF process immediately shuts down. It
notifies the system that OSPF has performed a graceful shutdown. Routes installed
by OSPF are preserved until the grace-period expires.
When a restart ospf graceful command is issued, the OSPF configuration is
reloaded from the last saved configuration. Ensure you first enter the command
copy running-config startup-config.
Example
awplus# copy running-config startup-config
awplus# restart ospf graceful grace-period 200
Related
commands
ospf restart grace-period
ospf restart helper
Parameter Description
grace-period Specify the grace period.
<1-1800> The grace period in seconds.