C613-50631-01 Rev A Command Reference for IE340 Series 814
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
POWER OVER ETHERNET COMMANDS
POWER
-INLINE ALLOW-LEGACY
power-inline allow-legacy
Overview This command enables detection of pre-IEEE 802.3af Power Ethernet standard
legacy powered devices (PDs).
The no variant of this command disables detection of pre-IEEE 802.3af Power
Ethernet standard legacy powered devices.
Syntax
power-inline allow-legacy
no power-inline allow-legacy
Default Detection of legacy PDs is disabled on all ports
Mode Global Configuration
Examples To enable detection of legacy PDs, use the following commands:
awplus# configure terminal
awplus(config)# power-inline allow-legacy
To disable detection of legacy PDs, use the following commands:
awplus# configure terminal
awplus(config)# no power-inline allow-legacy
Validation
Commands
show power-inline
show running-config power-inline
Command
changes
Version 5.4.8-0.2: added to x550 series products
Version 5.4.9-0.1: default changed to “disabled”